12722 12723 12724 12725 12726 12727 12728 12729 12730 12731 12732 12733 12734 12735 12736 12737 12738 12739 12740 12741 12742 12743 12744 12745 12746 12747 12748 12749 12750 12751 12752 12753 12754 12755 12756

Custom Simultaneous  

Simultaneous Test Instrumentation – ViCATS-LTS-Custom

Shown are(2)ViCATS-LTS-CUSTOM computer based test systems with graphical user interface; each system performs simultaneous tests on the oil and coolant passages of a Front Chain Cover. The machine is high volume (1 million + parts per year) and is robotically loaded and unloaded.
 
The ViCATS leak test systems measure air leakage on adjacent cavities simultaneously at different test pressures and automatically correlate the test results to 25.0 psig. The test specification is not to exceed 7.0 cc/m air leakage @ 25.0 psig. Total test time is (14) seconds, achieving a 4% Gage R & R.
 
The ViCATS leak test systems are controlled by an external PLC and have the capability to test and track both 3.7L and 4.7L parts. Each style part has its own test counters, timers, calibration, and limits.
Exhaust Manifold
Exhaust Manifold