Shown are (2)
ViCATS-LTS-CUSTOM computer
based test systems with graphical user interface, each performing
simultaneous tests on the oil and coolant passages of a Front Cover. The machine
is high volume machine (1 million + parts per year) and is robotically
loaded and unloaded.
The ViCATS
leak test systems measure leakage on adjacent cavities at different test
pressures and automatically correlate the results to 25 psig. The test
specifications are not to exceed 7 cc/m at 25 psig. The cavities are tested
simultaneously and the total test time is 14 seconds, achieving a 4% Gage R
& R.
The ViCATS leak test
systems are controlled by an external PLC and have the capability to test
and track both 3.7L and 4.7L parts. Each style part has it’s own test
counters, timers, calibration, and limits.
|