Test Instrumentation – ViCATS-LTS Custom Simultaneous

Shown are (2) ViCATS-LTS-CUSTOM computer based test systems with graphical user interface, each performing simultaneous tests on the oil and coolant passages of a Front Cover. The machine is high volume machine (1 million + parts per year) and is robotically loaded and unloaded.

 

The ViCATS leak test systems measure leakage on adjacent cavities at different test pressures and automatically correlate the results to 25 psig. The test specifications are not to exceed 7 cc/m at 25 psig. The cavities are tested simultaneously and the total test time is 14 seconds, achieving a 4% Gage R & R.

 

The ViCATS leak test systems are controlled by an external PLC and have the capability to test and track both 3.7L and 4.7L parts. Each style part has it’s own test counters, timers, calibration, and limits.